ATEX zone 1 vs 2 and zone 21 vs 22: which equipment where?
ATEX determines which equipment you may install in a hazardous area. To do that, you divide the area into zones. Zones 1 and 2 cover gas and vapour. Zones 21 and 22 cover dust. This article explains the difference and shows which equipment category belongs to which zone.
What do the ATEX zones mean?
A zone describes how often an explosive atmosphere occurs. The plant operator decides the zone classification. The equipment manufacturer supplies equipment for the stated zone.
| Zone (gas) | Zone (dust) | Likelihood of an explosive atmosphere |
|---|---|---|
| Zone 0 | Zone 20 | Present continuously, for long periods or often |
| Zone 1 | Zone 21 | May occur occasionally in normal operation |
| Zone 2 | Zone 22 | Not normally present, and if so only briefly |
Zone 1 or zone 2: gas and vapour
Zone 1 applies where flammable gas or vapour may occasionally be present in normal operation. Zone 2 applies where that only happens briefly, during a fault. Think of solvent vapour near a centrifuge or dryer. Zone 1 sets stricter requirements for equipment than zone 2.
Zone 21 or zone 22: combustible dust
Zone 21 applies where a dust cloud may occasionally occur in normal operation, for example when filling or emptying powder. Zone 22 applies where that does not normally happen and only occurs briefly. Dust deposits also count, because disturbed dust can still form a cloud.
Which equipment category belongs to which zone?
| Zone | Equipment category |
|---|---|
| Zone 0 (gas) / Zone 20 (dust) | Category 1 (1G / 1D) |
| Zone 1 (gas) / Zone 21 (dust) | Category 2 (2G / 2D), or category 1 |
| Zone 2 (gas) / Zone 22 (dust) | Category 3 (3G / 3D), or category 1 or 2 |
The letter G stands for gas, the letter D for dust. Equipment of a higher category may also be used in a zone with a lower requirement. Not the other way round.
What else should you consider?
- Temperature: the surface of equipment must not get hotter than the ignition temperature of the gas or dust.
- Type of dust: conductive and non-conductive dust set different requirements.
- Inside and outside: the zone inside a filling system can be higher than that in the room around it. Assess both separately.
- Documentation: record the zone classification and measures in an explosion protection document.
ATEX in powder handling
With powders, dust arises mainly during filling, emptying, dosing and transport. A closed design limits dust and therefore the zone. See our filling systems and read filling powders: big bag, drum or bag. Also see our page on containment.
In short: zones 1 and 2 cover gas, zones 21 and 22 cover dust. The lower the zone number, the more often an explosive atmosphere occurs and the higher the requirements for equipment. Category 2 belongs to zones 1 and 21, category 3 to zones 2 and 22. Always have the zone classification set by an expert. Get in touch with questions about ATEX-suitable powder handling.