Description

The containment drum emptying with suction lance type CFE-L is a HECHT system for the closed emptying of drums with inliner up to OEB 5, standard practice in the pharmaceutical industry. An automatic lifting device positions and connects the drum, after which the operator handles the suction lance via gloves with clear view of the product flow — the product is drawn off, ideal for very confined spaces or weight-controlled product removal directly to a weighing system or dosing installation. The connection is contamination-free thanks to double O-ring technology, which always keeps the product side separated from the environment during connection and disconnection, and the product must be packed in at least one liner. The ergonomic handling won the Technology Award in 2016. For explosion-hazardous environments an ATEX version is available, inertisation is possible for oxygen-sensitive products, and the system integrates easily into roller conveyor systems, with WIP integration possible at any time.


Customer benefits

  • Containment drum discharging up to OEB 5, OEL < 1µ/m³
  • Monitoring of the product flow
  • Ergonomic handling
  • Smooth product handling with gloves
  • Changing gloves is both smooth and contamination-free
  • Contamination-free connection thanks to double O-ring technology
  • Automatic lifting device for positioning and docking the drum
  • Easy integration into roller conveyor systems
  • Hygienic design or ATEX version available
  • WIP integration possible at any time
  • Inertisation
  • Various materials and surfaces

Frequently asked questions about CFE-L emptying drums with suction lance

How does containment drum emptying with a suction lance work?

The CFE-L empties drums with inliner in a fully closed manner up to OEB 5. The automatic lifting device positions and connects the drum; the operator handles the suction lance via gloves with a clear view of the product flow. The product is drawn off via the lance — ideal for very confined spaces or weight-controlled product removal, for example directly to a weighing system or dosing installation.

How is contamination prevented when connecting and disconnecting?

The connection is contamination-free thanks to double O-ring technology: the product side always stays separated from the environment during connection and disconnection. Changing gloves is also smooth and contamination-free. The product must be packed in at least one liner — standard practice in the pharmaceutical industry to protect both operator and product.

Which containment level is the CFE-L suitable for?

The CFE-L is designed for closed drum emptying up to OEB 5 (OEL level), as required when processing HPAPIs and other highly active substances. For explosion-hazardous environments an ATEX version is available; inertisation is possible for oxygen-sensitive products.

Which versions and integration options are available?

The CFE-L is available in hygienic design or ATEX version, with various materials and surface finishes. WIP integration (Wash-In-Place) is possible at any time for validated cleaning. The station integrates easily into roller conveyor systems for continuous drum logistics. The ergonomic handling was awarded the Technology Award in 2016.


Containment level

OEB Level 5
Enquire now

Technology

Handling in the video

  • Drum is rolled directly under the glovebox using a roller conveyor
  • Lifting device brings the drum into position
  • Operator attaches the outer liner to the double O-ring port with a clamping ring
  • Remains of the previous liner are removed with the gloves and stored temporarily
  • Drum is pressed against the seal of the box with the lifting device and fixed in place
  • Inner liner (product liner) is opened, stabilised and sealed with an inflatable seal
  • The area between the drum and the outer liner is evacuated to prevent the liner from being sucked in
  • Powder is sucked out of the drum using a suction lance and vacuum
  • Linear guidance of the suction lance supports ergonomic handling during emptying
  • Remains of the previous liner can be disposed of in the emptied drum
  • Double closure system is used to securely close the drum
  • Empty drum is removed, cycle starts again
Uw optimale websitegebruik
Deze website gebruikt cookies en integreert externe media. Door op “✓ Alles accepteren” te klikken, kiest u voor een optimale webervaring en stemt u in met de weergave van externe content. U kunt meer informatie vinden en uw persoonlijke voorkeuren instellen onder “Instellingen”. Meer informatie vindt u in ons Privacybeleid.

Gedetailleerde informatie over het gebruik van cookies en externe media.
Externe media omvatten video's of iframes van andere platforms die op deze website zijn ingesloten. Deze cookies bevatten geanonimiseerde informatie over uw bezoek aan deze website, wat uw gebruikerservaring verbetert. Om de website optimaal te laten functioneren, moet u actief instemmen met het gebruik van deze cookies. U kunt uw persoonlijke instellingen hier configureren. Heeft u nog vragen? Lees meer over uw rechten als gebruiker in het Privacybeleid en de Juridische disclaimer!